The 6" Round Fire-rated Canless Recessed Light is a high-safety LED solution engineered for 2-hour fire-resistant ceiling assemblies. Delivering 1000 lumens at 12W, this ETL-certified fixture features 5CCT selectable technology, CRI 90 accuracy, and a wet-location rating. Its integrated junction box and canless design provide a code-compliant, efficient installation for demanding professional projects.

  • Model :

    UFOR56-B-FH-5C-WH
  • Wattage :

    12W
  • Lumen :

    1000LM
  • Color Temperature :

    2700K/3000K/3500K/4000K/5000K
  • Voltage :

    120V/60Hz
  • CRI :

    90
  • Hole size :

    150mm
  • Average Life :

    50000H
  • Certificate :

    UL, ETL, Title 24/JA8, FCC
Inquiry now

6" Round Fire-rated Canless Recessed Light

Safety-First Canless Lighting for Professional Specification.

 

Enhanced Fire Safety: Engineered to meet strict building codes with a 2-hour fire rating for protected ceiling assemblies.

Selectable Ambiance: On-fixture 5CCT toggle (27K to 50K) allows for instant site-specific lighting adjustments.

Simplified Rough-In: Ultra-slim canless design with quick-connect wiring eliminates the need for traditional housings.

 

 

Product Features

Fire-Resistant Coating: The hanger bars hasrecessed section that can besnapped off to accommodate shorter beam spacing.

Ultra-thin design : The product featuresholes for fixing the junction box,facilitating secure installation.

Fireproof Cable Lock: The hanger bars hasrecessed section that can besnapped off to accommodate shorter beam spacing.

Steel Mounting Clip : The product featuresholes for fixing the junction box,facilitating secure installation.

 

 

FT6 Flame Retardant Cable for Plenum Applications 

 

The fire-rated fixture is equipped with a high-spec FT6 (Plenum) rated cable. This superior flame retardant grade ensures minimal smoke emission and flame spread during a fire event. It is suitable for installation in air-handling spaces (Plenums) and critical fire-rated ceiling assemblies, providing an extra layer of protection for high-occupancy projects.

5CCT Selectable Technology

 

Maximize project flexibility with the integrated color temperature selector. Contractors can switch between 2700K, 3000K, 3500K, 4000K, and 5000K on-site, ensuring the lighting perfectly matches the final interior design while reducing the number of SKUs required for a job.

2700K -  Warm  &  Cozy

Soft, warm light for a relaxed and inviting atmosphere.

3000K -  Warm  &  Comfortable

A balanced warm tone for comfortable everyday lighting.

3500K -  Soft  &  Neutral

A gentle neutral light that feels natural and versatile.

4000K -  Clean  &  Bright

Crisp, neutral illumination for a fresh and focused space.

5000K -  Clear  &  Energizing

Bright, cool-white light for maximum clarity and visibility.

Quick-connect terminals

 

The pre-wired junction box includes high-quality quick-connect push wire nuts, facilitating tool-free electrical connections. This design significantly speeds up the wiring process during the rough-in stage, reducing labor costs and ensuring secure, long-term performance.

 

  •  

Compatible Mounting Plates & Frames

 

This fire-rated light is fully compatible with our precision-engineered New Construction Mounting Plates and Hanger Bar Frames. These accessories provide extra stability and accurate positioning during the framing phase, ensuring a consistent and professional finished ceiling layout.

 

 

 

 

 

Installation Instructions

Installation for LED  5"/6"  Retrofit Trim

 

1. Make sure the power is turned off at the source to the recessedhousing(s) where the fixture(s) will be installed. Remove existing trimand CFL or incandescent bulbs.

 

2. Plug the female connector of the retrofit-kit into the male connector of housing assembly. (Fig. 2). If you used E26 socket,please screw E26 socket adapter into socket in housing. (Fig. 1)

 

 

3. Squeeze the torsion springs together as shown and install intotorsion spring brackets inside the housing. (Fig. 4)

 

4. Tuck all wire into the housing and carefully push the RETROFIT TRIMup flush to ceiling surface.

 


 

 

 

 

Q1:What is the fire rating of this light?

A:This fixture is designed and tested for 2-hour fire-rated ceiling applications.

Q2:What is the flame retardant grade of the cable?

A:The fixture is equipped with a premium FT6 (Plenum) rated flame retardant cable for maximum safety.

Q3:Is a separate housing needed for installation?

A:No, the canless design includes an integrated junction box for direct ceiling installation.

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Contact us:melody@omdlighting.com

Home

Products

WhatsApp

contact